| Assessment Year | 2008 |
|---|---|
| Principal Product | Thermoformed Plastic Packaging |
| NAICS | 561910: Packaging and Labeling Services |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
63,000
ft2
|
| Annual Production | 50,000,000
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $150,987 | 2,436,000 |
kWh
|
$0.062 |
| Electricity Demand | $56,772 | 6,528 |
kW-mo/yr
|
$8.70 |
| Electricity Fees | $(-14,276.0) | - |
|
- |
| LPG | $22,120 | 67 |
MMBtu
|
$330.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $107,252 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $31,658 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $19,525 | - |
$19,525
275,000
kWh
|
- | |
| 02 | 2.4224: Upgrade controls on compressors | $9,089 | $10,000 |
$9,089
128,014
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,807 | $160 |
$1,807
25,454
kWh
|
- | |
| 04 | 2.2511: Insulate bare equipment | $1,472 | $268 |
$1,472
20,720
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $165 | $127 |
$165
2,328
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,968 | $36,000 |
$11,756
165,580
kWh
|
$212
-
kW-mo/yr
|
|
| 07 | 2.9114: Use solar heat to make electricty | $63,226 | $1,600,000 |
$63,226
285,000
kWh
|
- | |
| TOTAL RECOMMENDED | $107,252 | $1,646,555 |
$107,040
902,096
kWh
|
$212
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $31,658 | $36,127 |
$31,446
442,908
kWh
|
$212
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs