Assessment Year | 2022 |
---|---|
Principal Product | Frozen buns |
NAICS | 493120: Refrigerated Warehousing and Storage |
SIC | 4222: Refrigerated Warehousing and Storage |
Sales Range | greater than $500 M |
# of Employees | 215 |
Plant Area |
158,000
ft2
|
Annual Production | 15,000,000
pieces
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $273,391 | 4,231,929 |
kWh
|
$0.065 | |
Electricity Demand | $54,335 | 8,064 |
kW-mo/yr
|
$6.74 | |
Electricity Fees | $1,810 | - |
|
- | |
Natural Gas | $21,126 | 3,237 |
MMBtu
|
$6.53 | |
Waste Disposal Costs | |||||
Water Usage | $19,077 | 4,638 |
Tgal
|
$4.11 | |
Water Disposal | $12,727 | 2,026 |
Tgal
|
$6.28 | |
Solid Waste (non-haz) | $5,672 | 101,192 |
lb
|
$0.056 | |
TOTAL YEARLY COSTS | $388,137 | ||||
RECOMMENDED SAVINGS* | $275,801 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,407 | $100 |
$1,407
21,991
kWh
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,378 | $47,373 |
$17,378
271,532
kWh
|
- | - | |
03 | 2.3142: User battery storage for power quality issues | $230,341 | $287,555 | - | - | $230,341 | |
04 | 4.112: Replace old machine with new automatic multi-station tool | $7,380 | - | - | - | $7,380 | |
05 | 4.426: Modify workload | $16,860 | - |
$16,860
262,215
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $929 | $1,866 |
$929
14,509
kWh
|
- | - | |
07 | 3.4159: Replace treated water with well / surface water | $1,505 | $2,582 | - |
$1,667
-
Tgal
|
$(-161.6) | |
TOTAL RECOMMENDED | $275,801 | $339,476 |
$36,574
570,247
kWh
|
$1,667
-
Tgal
|
$237,560 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs