Assessment Year | 2016 |
---|---|
Principal Product | Machined parts for semiconductor manufacturing equipment |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 100 |
Plant Area |
77,912
ft2
|
Annual Production | 90
units
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Montana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,024 | 2,965,540 |
kWh
|
$0.039 |
Electricity Demand | $60,803 | 10,013 |
kW-mo/yr
|
$6.07 |
Electricity Fees | $1,986 | - |
|
- |
Natural Gas | $30,797 | 4,630 |
MMBtu
|
$6.65 |
TOTAL YEARLY COSTS | $208,610 | |||
RECOMMENDED SAVINGS* | $27,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,590 | $1,680 |
$7,040
175,800
kWh
|
$1,550
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,690 | $20,770 |
$4,690
117,000
kWh
|
- | - | - | - | |
03 | 2.2514: Cover open tanks | $7,390 | $12,880 | - | - |
$7,390
-
MMBtu
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,620 | $11,750 |
$6,270
156,500
kWh
|
$1,560
-
kW-mo/yr
|
- | $200 | $(-1,410.0) | |
TOTAL RECOMMENDED | $27,290 | $47,080 |
$18,000
449,300
kWh
|
$3,110
-
kW-mo/yr
|
$7,390
-
MMBtu
|
$200 | $(-1,410.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs