| Assessment Year | 2016 |
|---|---|
| Principal Product | Machined parts for semiconductor manufacturing equipment |
| NAICS | 332710: Machine Shops |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
77,912
ft2
|
| Annual Production | 90
units
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Montana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $115,024 | 2,965,540 |
kWh
|
$0.039 |
| Electricity Demand | $60,803 | 10,013 |
kW-mo/yr
|
$6.07 |
| Electricity Fees | $1,986 | - |
|
- |
| Natural Gas | $30,797 | 4,630 |
MMBtu
|
$6.65 |
| TOTAL YEARLY COSTS | $208,610 | |||
| RECOMMENDED SAVINGS* | $27,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,590 | $1,680 |
$7,040
175,800
kWh
|
$1,550
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,690 | $20,770 |
$4,690
117,000
kWh
|
- | - | - | - | |
| 03 | 2.2514: Cover open tanks | $7,390 | $12,880 | - | - |
$7,390
-
MMBtu
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,620 | $11,750 |
$6,270
156,500
kWh
|
$1,560
-
kW-mo/yr
|
- | $200 | $(-1,410.0) | |
| TOTAL RECOMMENDED | $27,290 | $47,080 |
$18,000
449,300
kWh
|
$3,110
-
kW-mo/yr
|
$7,390
-
MMBtu
|
$200 | $(-1,410.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs