Assessment Year | 2015 |
---|---|
Principal Product | Bakery Products |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
31,600
ft2
|
Annual Production | 16,640,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,738 | 1,599,360 |
kWh
|
$0.046 |
Electricity Demand | $76,811 | 3,513 |
kW-mo/yr
|
$21.86 |
Electricity Fees | $616 | - |
|
- |
Natural Gas | $69,667 | 11,820 |
MMBtu
|
$5.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,140 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2626: Avoid frost formation on evaporators | $6,920 | $5,420 |
$6,920
162,200
kWh
|
- | - | - | - | |
02 | 2.2628: Utilize a less expensive cooling method | $3,300 | $11,250 |
$1,940
45,600
kWh
|
$1,360
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,120 | $130 |
$1,230
28,800
kWh
|
$890
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $1,460 | $3,280 |
$830
19,400
kWh
|
$630
-
kW-mo/yr
|
- | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $760 | $1,820 |
$370
8,600
kWh
|
$390
-
kW-mo/yr
|
- | - | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $7,870 | $500 | - | - | - | $7,870 | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,710 | $13,850 |
$2,790
65,500
kWh
|
$2,210
-
kW-mo/yr
|
$40 | - | $670 | |
TOTAL RECOMMENDED | $28,140 | $36,250 |
$14,080
330,100
kWh
|
$5,480
-
kW-mo/yr
|
$40 | $7,870 | $670 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs