Assessment Year | 2014 |
---|---|
Principal Product | Oil & Gas Well Optimization Equipment |
NAICS | 333911: Pump and Pumping Equipment Manufacturing |
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $100 M to 500M |
# of Employees | 390 |
Plant Area |
45,700
ft2
|
Annual Production | 420,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,335 | 1,205,760 |
kWh
|
$0.058 |
Electricity Demand | $43,151 | 2,400 |
kW-mo/yr
|
$17.98 |
Electricity Fees | $756 | - |
|
- |
Natural Gas | $4,454 | 576 |
MMBtu
|
$7.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,460 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,320 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,210 | $2,210 |
$3,770
62,100
kWh
|
$1,440
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,220 | $6,060 |
$2,090
34,400
kWh
|
$980
-
kW-mo/yr
|
$60 | - | $90 | |
03 | 2.8121: Apply for tax-free status for energy purchases | $3,110 | $1,500 | - | - | - | $3,110 | - | |
04 | 2.7135: Install occupancy sensors | $1,920 | $2,480 |
$1,800
29,700
kWh
|
- | $30 | - | $90 | |
TOTAL RECOMMENDED | $13,460 | $12,250 |
$7,660
126,200
kWh
|
$2,420
-
kW-mo/yr
|
$90 | $3,110 | $180 | ||
TOTAL IMPLEMENTED | $8,320 | $3,710 |
$3,770
62,100
kWh
|
$1,440
-
kW-mo/yr
|
- | $3,110 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs