Assessment Year | 2014 |
---|---|
Principal Product | Data Storage Tape Decks |
NAICS | 334112: Computer Storage Device Manufacturing |
SIC | 3572: Computer Storage Devices |
Sales Range | $100 M to 500M |
# of Employees | 370 |
Plant Area |
84,400
ft2
|
Annual Production | 2,000
pieces
|
Production Hrs. Annual | 3,619
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $153,618 | 3,463,019 |
kWh
|
$0.044 |
Electricity Demand | $150,440 | 6,930 |
kW-mo/yr
|
$21.71 |
Electricity Fees | $1,266 | - |
|
- |
Natural Gas | $9,597 | 1,281 |
MMBtu
|
$7.49 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $40,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,540 | $21,440 |
$6,450
134,700
kWh
|
$8,240
-
kW-mo/yr
|
$290 | $1,560 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,750 | $13,140 |
$7,870
164,400
kWh
|
$4,880
-
kW-mo/yr
|
- | - | |
03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $8,270 | - |
$4,770
99,600
kWh
|
$3,500
-
kW-mo/yr
|
- | - | |
04 | 2.2691: Shut off cooling if cold outside air will cool process | $2,440 | $6,450 |
$1,890
39,500
kWh
|
$550
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $40,000 | $41,030 |
$20,980
438,200
kWh
|
$17,170
-
kW-mo/yr
|
$290 | $1,560 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs