Assessment Year | 2012 |
---|---|
Principal Product | Crushed Aggregates |
NAICS | 327999: All Other Miscellaneous Nonmetallic Mineral Product Manufacturing |
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $500 k to 1M |
# of Employees | 4 |
Plant Area |
12,930
ft2
|
Annual Production | 507
units
|
Production Hrs. Annual | 1,820
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $12,013 | 222,120 |
kWh
|
$0.054 |
Electricity Demand | $145,284 | 4,733 |
kW-mo/yr
|
$30.70 |
Electricity Fees | $1,408 | - |
|
- |
Fuel Oil #2 | $5,044 | 212 |
MMBtu
|
$23.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $91,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,060 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $26,390 | $1,000 |
$1,310
24,200
kWh
|
$25,080
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,260 | $340 |
$750
13,800
kWh
|
$2,510
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,020 | $2,860 |
$50
900
kWh
|
$2,970
-
kW-mo/yr
|
- | - | - | |
04 | 2.8114: Change rate schedules or other changes in utility service | $52,770 | $500 |
$4,290
-
kWh
|
$50,170
-
kW-mo/yr
|
- | $(-1,690.0) | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $4,410 | $500 | - | - | - | $4,410 | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,150 | $4,670 |
$190
3,600
kWh
|
$940
-
kW-mo/yr
|
$10 | - | $10 | |
TOTAL RECOMMENDED | $91,000 | $9,870 |
$6,590
42,500
kWh
|
$81,670
-
kW-mo/yr
|
$10 | $2,720 | $10 | ||
TOTAL IMPLEMENTED | $34,060 | $1,840 |
$2,060
38,000
kWh
|
$27,590
-
kW-mo/yr
|
- | $4,410 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs