Assessment Year 2011
Principal Product Lumber
NAICS 321113: Sawmills
SIC 2421: Sawmills and Planing Mills, General
Sales Range $1
M
to 5
M
# of Employees 30
Plant Area 24,500
ft2
Annual Production 3,000,000
pieces
Production Hrs. Annual 1,872
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $12,904 346,880
kWh
Electricity Demand $57,436 3,008
kW-mo/yr
Electricity Fees $483 -
Fuel Oil #2 $113,120 4,200
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $7,890 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,440

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $1,240 $5,950 $120
3,000
kWh
$1,120
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,490 $520 $590
15,400
kWh
$1,900
-
kW-mo/yr
-
03 2.4323: Use optimum size and capacity equipment $950 $600 $100
2,700
kWh
$850
-
kW-mo/yr
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $790 $1,410 $80
2,100
kWh
$710
-
kW-mo/yr
-
05 2.9114: Use solar heat to make electricty $2,420 $27,500 $600
15,600
kWh
$1,200
-
kW-mo/yr
$620
TOTAL RECOMMENDED $7,890 $35,980 $1,490
38,800
kWh
$5,780
-
kW-mo/yr
$620
TOTAL IMPLEMENTED $3,440 $1,120 $690
18,100
kWh
$2,750
-
kW-mo/yr
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs