Assessment Year | 2011 |
---|---|
Principal Product | Lumber |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
24,500
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 1,872
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $12,904 | 346,880 |
kWh
|
$0.037 |
Electricity Demand | $57,436 | 3,008 |
kW-mo/yr
|
$19.09 |
Electricity Fees | $483 | - |
|
- |
Fuel Oil #2 | $113,120 | 4,200 |
MMBtu
|
$26.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,890 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,440 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,240 | $5,950 |
$120
3,000
kWh
|
$1,120
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,490 | $520 |
$590
15,400
kWh
|
$1,900
-
kW-mo/yr
|
- | |
03 | 2.4323: Use optimum size and capacity equipment | $950 | $600 |
$100
2,700
kWh
|
$850
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $790 | $1,410 |
$80
2,100
kWh
|
$710
-
kW-mo/yr
|
- | |
05 | 2.9114: Use solar heat to make electricty | $2,420 | $27,500 |
$600
15,600
kWh
|
$1,200
-
kW-mo/yr
|
$620 | |
TOTAL RECOMMENDED | $7,890 | $35,980 |
$1,490
38,800
kWh
|
$5,780
-
kW-mo/yr
|
$620 | ||
TOTAL IMPLEMENTED | $3,440 | $1,120 |
$690
18,100
kWh
|
$2,750
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs