| Assessment Year | 2010 |
|---|---|
| Principal Product | Plastic Bags |
| NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
| SIC | 2673: Plastics, Foil, and Coated Paper Bags |
| Sales Range | $10 M to 50M |
| # of Employees | 68 |
| Plant Area |
40,000
ft2
|
| Annual Production | 14,400,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $201,266 | 5,366,000 |
kWh
|
$0.038 |
| Electricity Demand | $130,333 | 8,550 |
kW-mo/yr
|
$15.24 |
| Electricity Fees | $1,752 | - |
|
- |
| Natural Gas | $24,636 | 3,738 |
MMBtu
|
$6.59 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,650 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $30,960 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,720 | $1,140 |
$7,400
161,400
kWh
|
$4,320
-
kW-mo/yr
|
- | - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $8,870 | $3,410 |
$4,990
108,800
kWh
|
$3,880
-
kW-mo/yr
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,900 | $2,650 |
$2,160
47,200
kWh
|
$1,740
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,710 | $18,500 |
$11,920
260,100
kWh
|
$6,940
-
kW-mo/yr
|
$130 | $(-280.0) | |
| 05 | 2.9114: Use solar heat to make electricty | $1,920 | $35,000 |
$710
15,600
kWh
|
$1,210
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $530 | $3,060 |
$350
7,700
kWh
|
$210
-
kW-mo/yr
|
$20 | $(-50.0) | |
| TOTAL RECOMMENDED | $45,650 | $63,760 |
$27,530
600,800
kWh
|
$18,300
-
kW-mo/yr
|
$150 | $(-330.0) | ||
| TOTAL IMPLEMENTED | $30,960 | $22,700 |
$19,670
429,200
kWh
|
$11,470
-
kW-mo/yr
|
$150 | $(-330.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs