Assessment Year | 2010 |
---|---|
Principal Product | Tortillas and tortilla chips |
NAICS | 311830: Tortilla Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 261 |
Plant Area |
33,000
ft2
|
Annual Production | 75,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $218,845 | 5,494,320 |
kWh
|
$0.040 |
Electricity Demand | $155,740 | 10,290 |
kW-mo/yr
|
$15.14 |
Electricity Fees | $3,422 | - |
|
- |
Natural Gas | $474,930 | 72,330 |
MMBtu
|
$6.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,330 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $6,080 | $1,630 |
$3,110
74,200
kWh
|
$2,970
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,910 | $390 |
$3,000
71,600
kWh
|
$2,910
-
kW-mo/yr
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $3,170 | $4,860 |
$2,110
50,500
kWh
|
$1,060
-
kW-mo/yr
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $1,420 | $9,910 |
$900
21,400
kWh
|
$520
-
kW-mo/yr
|
- | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $760 | $4,430 |
$450
10,800
kWh
|
$310
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,460 | $16,020 |
$5,090
121,500
kWh
|
$2,540
-
kW-mo/yr
|
$200 | $(-370.0) | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,920 | $23,640 |
$1,310
31,200
kWh
|
$660
-
kW-mo/yr
|
$70 | $880 | |
08 | 2.9114: Use solar heat to make electricty | $1,600 | $10,500 |
$650
15,600
kWh
|
$950
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,160 | $1,170 |
$140
3,300
kWh
|
$80
-
kW-mo/yr
|
$430 | $510 | |
TOTAL RECOMMENDED | $30,480 | $72,550 |
$16,760
400,100
kWh
|
$12,000
-
kW-mo/yr
|
$700 | $1,020 | ||
TOTAL IMPLEMENTED | $15,330 | $17,530 |
$7,600
181,300
kWh
|
$6,790
-
kW-mo/yr
|
$430 | $510 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs