Assessment Year | 2009 |
---|---|
Principal Product | Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
35,000
ft2
|
Annual Production | 27,400
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,144 | 1,840,400 |
kWh
|
$0.041 |
Electricity Demand | $72,552 | 4,768 |
kW-mo/yr
|
$15.22 |
Electricity Fees | $347 | - |
|
- |
Natural Gas | $11,068 | 1,330 |
MMBtu
|
$8.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,490 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,250 | $1,000 |
$3,300
89,500
kWh
|
$2,950
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,280 | $15,890 |
$5,280
143,200
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $970 | $4,840 |
$430
11,700
kWh
|
$540
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,140 | $8,210 |
$2,240
60,700
kWh
|
$2,820
-
kW-mo/yr
|
$80 | |
05 | 2.9114: Use solar heat to make electricty | $1,850 | $17,500 |
$540
14,600
kWh
|
$1,310
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $19,490 | $47,440 |
$11,790
319,700
kWh
|
$7,620
-
kW-mo/yr
|
$80 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs