| Assessment Year | 2009 |
|---|---|
| Principal Product | Tungsten metal powder |
| NAICS | 331492: Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) |
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 7 |
| Plant Area |
11,000
ft2
|
| Annual Production | 30,900
lb
|
| Production Hrs. Annual | 2,184
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $51,156 | 1,076,872 |
kWh
|
$0.048 |
| Electricity Demand | $52,065 | 3,088 |
kW-mo/yr
|
$16.86 |
| Electricity Fees | $384 | - |
|
- |
| Natural Gas | $52,649 | 5,505 |
MMBtu
|
$9.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,970 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $310 | $1,730 | - | - |
$310
-
MMBtu
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,570 | $3,690 |
$860
22,600
kWh
|
$650
-
kW-mo/yr
|
- | $30 | $30 | |
| 03 | 2.9114: Use solar heat to make electricty | $1,780 | $10,500 |
$560
14,600
kWh
|
$1,220
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $930 | $4,360 |
$310
8,200
kWh
|
$650
-
kW-mo/yr
|
- | $10 | $(-40.0) | |
| 05 | 2.4133: Use most efficient type of electric motors | $600 | $1,010 |
$350
9,300
kWh
|
$250
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $400 | $510 |
$90
2,400
kWh
|
$60
-
kW-mo/yr
|
- | $130 | $120 | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $360 | $650 |
$210
5,500
kWh
|
$150
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $5,950 | $22,450 |
$2,380
62,600
kWh
|
$2,980
-
kW-mo/yr
|
$310
-
MMBtu
|
$170 | $110 | ||
| TOTAL IMPLEMENTED | $1,970 | $4,200 |
$950
25,000
kWh
|
$710
-
kW-mo/yr
|
- | $160 | $150 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs