Assessment Year | 2008 |
---|---|
Principal Product | Jewelry and jewelry-making equipment |
NAICS | 339910: Jewelry and Silverware Manufacturing |
SIC | 3911: Jewelry, Precious Metal |
Sales Range | $100 M to 500M |
# of Employees | 390 |
Plant Area |
187,500
ft2
|
Annual Production | 1,040,000
pieces
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | New Mexico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $129,755 | 2,838,700 |
kWh
|
$0.046 |
Electricity Demand | $63,149 | 10,734 |
kW-mo/yr
|
$5.88 |
Electricity Fees | $78,803 | - |
|
- |
Natural Gas | $28,894 | 2,779 |
MMBtu
|
$10.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,720 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,670 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3137: Use power during off-peak periods | $15,050 | - |
$15,050
266,600
kWh
|
- | - | - | - | - | |
02 | 2.6242: Minimize operation of equipment maintained in standby condition | $19,720 | $10,000 |
$19,720
478,700
kWh
|
- | - | - | - | - | |
03 | 2.9114: Use solar heat to make electricty | $5,170 | $61,600 |
$1,270
21,800
kWh
|
$1,070
-
kW-mo/yr
|
- | - | $2,830 | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,950 | $42,300 |
$(-1,350.0)
(-28,900)
kWh
|
$(-520.0)
-
kW-mo/yr
|
$3,820
-
MMBtu
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $1,780 | $50,000 |
$790
13,500
kWh
|
$770
-
kW-mo/yr
|
- | $10 | - | $210 | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $1,050 | $640 |
$410
7,000
kWh
|
$530
-
kW-mo/yr
|
- | - | - | $110 | |
TOTAL RECOMMENDED | $44,720 | $164,540 |
$35,890
758,700
kWh
|
$1,850
-
kW-mo/yr
|
$3,820
-
MMBtu
|
$10 | $2,830 | $320 | ||
TOTAL IMPLEMENTED | $29,670 | $164,540 |
$20,840
492,100
kWh
|
$1,850
-
kW-mo/yr
|
$3,820
-
MMBtu
|
$10 | $2,830 | $320 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs