Assessment Year 2008
Principal Product Kitchen cabinets
NAICS 337110: Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434: Wood Kitchen Cabinets
Sales Range $1
M
to 5
M
# of Employees 383
Plant Area 385,000
ft2
Annual Production 484,000
pieces
Production Hrs. Annual 5,345
hrs
Location (State) New Mexico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $257,716 6,117,600
kWh
Electricity Demand $99,120 13,992
kW-mo/yr
Electricity Fees $69,283 -
Natural Gas $68,641 6,624
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $136,705 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.6218: Turn off equipment when not in use $15,060 $2,000 $10,640
181,300
kWh
$4,420
-
kW-mo/yr
- - - -
02 2.3137: Use power during off-peak periods $11,030 - $11,030
204,300
kWh
- - - - -
03 2.6218: Turn off equipment when not in use $2,850 - $2,850
70,600
kWh
- - - - -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,320 $7,440 $1,370
26,200
kWh
$950
-
kW-mo/yr
- - - -
05 2.4133: Use most efficient type of electric motors $525 $1,158 $310
5,918
kWh
$215
-
kW-mo/yr
- - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $72,640 $127,860 $51,410
1,081,200
kWh
$20,680
-
kW-mo/yr
- $670 - $(-120.0)
07 2.7122: Disconnect ballasts $22,520 $6,560 $15,430
329,000
kWh
$5,710
-
kW-mo/yr
- $1,830 - $(-450.0)
08 2.9114: Use solar heat to make electricty $5,120 $61,600 $1,280
21,800
kWh
$1,010
-
kW-mo/yr
- - $2,830 -
09 2.7243: Improve air circulation with destratification fans / other methods $4,640 $90,000 $(-2,870.0)
(-61,300)
kWh
$(-1,060.0)
-
kW-mo/yr
$8,570
-
MMBtu
- - -
TOTAL RECOMMENDED $136,705 $296,618 $91,450
1,859,018
kWh
$31,925
-
kW-mo/yr
$8,570
-
MMBtu
$2,500 $2,830 $(-570.0)
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs