Assessment Year | 2006 |
---|---|
Principal Product | Concrete pipe |
NAICS | 327332: Concrete Pipe Manufacturing |
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $5 M to 10M |
# of Employees | 11 |
Plant Area |
16,000
ft2
|
Annual Production | 40,000
ton
|
Production Hrs. Annual | 2,622
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $15,356 | 393,200 |
kWh
|
$0.039 |
Electricity Demand | $20,777 | 2,994 |
kW-mo/yr
|
$6.94 |
Electricity Fees | $813 | - |
|
- |
Natural Gas | $39,470 | 4,130 |
MMBtu
|
$9.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,710 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $4,730 | $3,350 | - | - |
$4,730
-
MMBtu
|
- | - | |
02 | 2.3212: Optimize plant power factor | $4,550 | $11,320 | - |
$4,550
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,300 | $6,900 |
$1,520
37,200
kWh
|
$1,780
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $150 | $442 |
$60
1,365
kWh
|
$90
-
kW-mo/yr
|
- | - | - | |
05 | 2.6218: Turn off equipment when not in use | $380 | - | - | - |
$380
-
MMBtu
|
- | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $3,200 | $5,050 | - | - |
$3,200
-
MMBtu
|
- | - | |
07 | 2.9114: Use solar heat to make electricty | $1,100 | $2,950 |
$620
15,200
kWh
|
$480
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $990 | $3,420 |
$450
10,900
kWh
|
$520
-
kW-mo/yr
|
- | - | $20 | |
09 | 2.8121: Apply for tax-free status for energy purchases | $950 | $500 | - | - | - | $950 | - | |
10 | 2.2136: Install / repair insulation on steam lines | $360 | $90 | - | - |
$360
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $19,710 | $34,022 |
$2,650
64,665
kWh
|
$7,420
-
kW-mo/yr
|
$8,670
-
MMBtu
|
$950 | $20 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs