Assessment Year | 2006 |
---|---|
Principal Product | Fluid milk products |
NAICS | 311511: Fluid Milk Manufacturing |
SIC | 2026: Fluid Milk |
Sales Range | $10 M to 50M |
# of Employees | 159 |
Plant Area |
110,000
ft2
|
Annual Production | 17,400
Tgal
|
Production Hrs. Annual | 4,888
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $251,823 | 7,102,439 |
kWh
|
$0.035 |
Electricity Demand | $217,856 | 20,172 |
kW-mo/yr
|
$10.80 |
Electricity Fees | $1,942 | - |
|
- |
Natural Gas | $84,612 | 9,551 |
MMBtu
|
$8.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,311 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,411 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $6,850 | $15,000 | - | - |
$6,850
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,420 | $180 |
$4,470
105,900
kWh
|
$1,950
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,160 | $3,230 |
$1,960
46,400
kWh
|
$1,200
-
kW-mo/yr
|
- | - | - | |
04 | 2.6218: Turn off equipment when not in use | $1,120 | - |
$370
8,700
kWh
|
$750
-
kW-mo/yr
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $142 | $194 |
$58
1,387
kWh
|
$84
-
kW-mo/yr
|
- | - | - | |
06 | 2.9111: Use solar heat to heat make-up air | $3,460 | $29,620 | - | - |
$3,460
-
MMBtu
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,720 | $3,590 |
$1,480
34,900
kWh
|
$1,120
-
kW-mo/yr
|
- | $70 | $50 | |
08 | 2.9114: Use solar heat to make electricty | $1,430 | $2,950 |
$600
14,100
kWh
|
$830
-
kW-mo/yr
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $719 | $110 |
$498
11,794
kWh
|
$265
-
kW-mo/yr
|
- | - | $(-44.0) | |
10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $290 | $200 |
$290
6,900
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $26,311 | $55,074 |
$9,726
230,081
kWh
|
$6,199
-
kW-mo/yr
|
$10,310
-
MMBtu
|
$70 | $6 | ||
TOTAL IMPLEMENTED | $11,411 | $4,274 |
$7,166
169,581
kWh
|
$4,169
-
kW-mo/yr
|
- | $70 | $6 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs