Assessment Year | 2006 |
---|---|
Principal Product | Glass Bottles |
NAICS | 327213: Glass Container Manufacturing |
SIC | 3221: Glass Containers |
Sales Range | $10 M to 50M |
# of Employees | 252 |
Plant Area |
336,200
ft2
|
Annual Production | 1,241,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,653,034 | 104,171,039 |
kWh
|
$0.045 |
Natural Gas | $6,186,291 | 1,034,390 |
MMBtu
|
$5.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $134,799 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $85,599 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,630 | $180 |
$9,060
200,600
kWh
|
$3,570
-
kW-mo/yr
|
- | - | - | |
02 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $10,760 | $10,000 |
$2,290
50,700
kWh
|
$3,120
-
kW-mo/yr
|
- | - | $5,350 | |
03 | 2.4323: Use optimum size and capacity equipment | $7,950 | $9,670 |
$5,700
126,100
kWh
|
$2,250
-
kW-mo/yr
|
- | - | - | |
04 | 2.4323: Use optimum size and capacity equipment | $4,080 | $500 |
$2,920
64,700
kWh
|
$1,160
-
kW-mo/yr
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $869 | $736 |
$623
13,785
kWh
|
$246
-
kW-mo/yr
|
- | - | - | |
06 | 2.6218: Turn off equipment when not in use | $1,380 | $1,150 |
$1,380
30,500
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $58,610 | $80,000 |
$43,870
971,100
kWh
|
$11,830
-
kW-mo/yr
|
- | $1,730 | $1,180 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,080 | $24,410 |
$19,010
421,000
kWh
|
$7,060
-
kW-mo/yr
|
- | $(-100.0) | $6,110 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,090 | $5,050 |
$2,370
52,400
kWh
|
$2,390
-
kW-mo/yr
|
- | $150 | $180 | |
10 | 2.1321: Replace fossil fuel equipment with electrical equipment | $1,020 | - |
$(-380.0)
(-8,500)
kWh
|
$(-160.0)
-
kW-mo/yr
|
$1,560
-
MMBtu
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $330 | $510 |
$140
3,100
kWh
|
$50
-
kW-mo/yr
|
- | $120 | $20 | |
TOTAL RECOMMENDED | $134,799 | $132,206 |
$86,983
1,925,485
kWh
|
$31,516
-
kW-mo/yr
|
$1,560
-
MMBtu
|
$1,900 | $12,840 | ||
TOTAL IMPLEMENTED | $85,599 | $92,576 |
$56,983
1,261,285
kWh
|
$18,656
-
kW-mo/yr
|
$1,560
-
MMBtu
|
$1,850 | $6,550 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs