Assessment Year | 2005 |
---|---|
Principal Product | Architectural millwork and fixtures |
NAICS | 337215: Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2426: Hardwood Dimension and Flooring Mills |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
86,700
ft2
|
Annual Production | 195
pieces
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,787 | 905,520 |
kWh
|
$0.034 |
Electricity Demand | $49,016 | 3,909 |
kW-mo/yr
|
$12.54 |
Electricity Fees | $480 | - |
|
- |
Natural Gas | $16,754 | 1,988 |
MMBtu
|
$8.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,750 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $2,890 | $4,100 | - | - |
$2,890
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,380 | $270 |
$460
12,700
kWh
|
$920
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $700 | $2,760 |
$230
6,500
kWh
|
$470
-
kW-mo/yr
|
- | - | - | |
04 | 2.2711: Utilize outside air instead of conditioned air for drying | $240 | $480 |
$80
2,200
kWh
|
$160
-
kW-mo/yr
|
- | - | - | |
05 | 2.7145: Install skylights | $10,440 | $90,000 |
$3,890
107,600
kWh
|
$6,020
-
kW-mo/yr
|
- | $200 | $330 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,460 | $29,920 |
$2,590
71,800
kWh
|
$4,120
-
kW-mo/yr
|
- | $680 | $1,070 | |
07 | 2.7135: Install occupancy sensors | $640 | $960 |
$560
15,600
kWh
|
- | - | $30 | $50 | |
TOTAL RECOMMENDED | $24,750 | $128,490 |
$7,810
216,400
kWh
|
$11,690
-
kW-mo/yr
|
$2,890
-
MMBtu
|
$910 | $1,450 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs