Assessment Year | 2003 |
---|---|
Principal Product | Solid surface materials |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
86,000
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New Mexico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $154,194 | 3,743,298 |
kWh
|
$0.041 |
Electricity Demand | $75,235 | 11,071 |
kW-mo/yr
|
$6.80 |
Electricity Fees | $69,146 | - |
|
- |
Natural Gas | $62,989 | 11,530 |
MMBtu
|
$5.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,287 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,000 | $15,440 |
$6,500
157,800
kWh
|
$3,930
-
kW-mo/yr
|
- | $570 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,260 | $550 |
$6,390
155,000
kWh
|
$3,870
-
kW-mo/yr
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $467 | $518 |
$246
5,182
kWh
|
$221
-
kW-mo/yr
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $960 | $2,310 |
$560
13,600
kWh
|
$400
-
kW-mo/yr
|
- | - | |
05 | 2.2511: Insulate bare equipment | $600 | $1,270 | - | - |
$600
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $23,287 | $20,088 |
$13,696
331,582
kWh
|
$8,421
-
kW-mo/yr
|
$600
-
MMBtu
|
$570 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs