| Assessment Year | 2002 |
|---|---|
| Principal Product | Magnesium extrusions |
| NAICS |
n/a
|
| SIC | 3356: Rolling, Drawing, and Extruding of Nonferrous Metals, Except Copper and Aluminum |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
112,700
ft2
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $106,722 | 6,558,361 |
kWh
|
$0.016 |
| Electricity Demand | $251,614 | 18,398 |
kW-mo/yr
|
$13.68 |
| Electricity Fees | $1,602 | - |
|
- |
| Natural Gas | $134,156 | 20,823 |
MMBtu
|
$6.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,400 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,580 | $600 |
$5,070
262,700
kWh
|
$4,870
-
kW-mo/yr
|
- | $(-360.0) | - | - | |
| 02 | 2.2511: Insulate bare equipment | $3,600 | $1,560 | - | - |
$3,600
-
MMBtu
|
- | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $320 | $480 |
$162
8,433
kWh
|
$158
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.7135: Install occupancy sensors | $1,210 | $300 |
$480
24,800
kWh
|
$730
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $580 | $1,450 |
$160
8,300
kWh
|
$150
-
kW-mo/yr
|
- | - | - | $270 | |
| 06 | 2.8121: Apply for tax-free status for energy purchases | $1,900 | $250 | - | - | - | - | $1,900 | - | |
| TOTAL RECOMMENDED | $17,190 | $4,640 |
$5,872
304,233
kWh
|
$5,908
-
kW-mo/yr
|
$3,600
-
MMBtu
|
$(-360.0) | $1,900 | $270 | ||
| TOTAL IMPLEMENTED | $15,400 | $2,890 |
$5,232
271,133
kWh
|
$5,028
-
kW-mo/yr
|
$3,600
-
MMBtu
|
$(-360.0) | $1,900 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs