Assessment Year | 2002 |
---|---|
Principal Product | Mining conveyor idlers |
NAICS |
n/a
|
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
88,500
ft2
|
Annual Production | 7,500,000
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $24,989 | 837,000 |
kWh
|
$0.030 |
Electricity Demand | $29,629 | 3,536 |
kW-mo/yr
|
$8.38 |
Electricity Fees | $1,245 | - |
|
- |
Natural Gas | $7,658 | 1,379 |
MMBtu
|
$5.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,080 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,910 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $2,920 | $8,000 | - |
$2,920
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,620 | $230 |
$950
31,800
kWh
|
$1,450
-
kW-mo/yr
|
- | $(-780.0) | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $640 | $2,260 |
$250
8,500
kWh
|
$390
-
kW-mo/yr
|
- | - | - | |
04 | 2.7141: Lower light fixtures in high ceiling areas | $610 | $1,920 |
$240
8,100
kWh
|
$370
-
kW-mo/yr
|
- | - | - | |
05 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $17,700 | $2,000 | - | - |
$1,890
-
lb
|
- | $15,810 | |
06 | 3.2176: Increase use of automation | $9,140 | $1,600 | - | - |
$540
-
lb
|
- | $8,600 | |
07 | 3.3122: Use filtration, centrifuging to remove contaminants | $2,450 | $1,330 | - | - | - | - | $2,450 | |
TOTAL RECOMMENDED | $35,080 | $17,340 |
$1,440
48,400
kWh
|
$5,130
-
kW-mo/yr
|
$2,430
-
lb
|
$(-780.0) | $26,860 | ||
TOTAL IMPLEMENTED | $30,910 | $5,160 |
$950
31,800
kWh
|
$1,450
-
kW-mo/yr
|
$2,430
-
lb
|
$(-780.0) | $26,860 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs