Assessment Year | 2000 |
---|---|
Principal Product | newspapers |
NAICS |
n/a
|
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $5 M to 10M |
# of Employees | 113 |
Plant Area |
40,000
ft2
|
Annual Production | 135
ton
|
Production Hrs. Annual | 1,300
hrs
|
Location (State) | Wyoming |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $37,879 | 1,523,447 |
kWh
|
$0.025 |
Electricity Demand | $36,117 | 3,803 |
kW-mo/yr
|
$9.50 |
Electricity Fees | $146 | - |
|
- |
Natural Gas | $9,011 | 2,352 |
MMBtu
|
$3.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,350 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $3,730 | $2,000 | - |
$3,730
-
kW-mo/yr
|
- | - | - | |
02 | 2.2437: Recover waste heat from equipment | $1,280 | $2,250 | - | - |
$1,280
-
MMBtu
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,840 | - |
$570
25,205
kWh
|
$630
-
kW-mo/yr
|
- | - | $640 | |
04 | 2.7135: Install occupancy sensors | $340 | $370 |
$240
10,551
kWh
|
$100
-
kW-mo/yr
|
- | - | - | |
05 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $320 | $1,040 | - | - |
$320
-
MMBtu
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $310 | $1,070 | - |
$120
-
kW-mo/yr
|
$190
-
MMBtu
|
- | - | |
07 | 3.6192: Use a less expensive method of waste removal | $530 | - | - | - | - |
$550
-
lb
|
$(-20.0) | |
TOTAL RECOMMENDED | $8,350 | $6,730 |
$810
35,756
kWh
|
$4,580
-
kW-mo/yr
|
$1,790
-
MMBtu
|
$550
-
lb
|
$620 | ||
TOTAL IMPLEMENTED | $2,180 | $370 |
$810
35,756
kWh
|
$730
-
kW-mo/yr
|
- | - | $640 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs