Assessment Year | 1997 |
---|---|
Principal Product | wood display cabinets & fixtures |
NAICS |
n/a
|
SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
Sales Range | $5 M to 10M |
# of Employees | 70 |
Plant Area |
80,000
ft2
|
Annual Production | 2,000
pieces
|
Production Hrs. Annual | 5,720
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,184 | 1,103,458 |
kWh
|
$0.017 |
Electricity Demand | $46,747 | 3,494 |
kW-mo/yr
|
$13.38 |
Electricity Fees | $216 | - |
|
- |
Natural Gas | $12,176 | 3,375 |
MMBtu
|
$3.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,825 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $635 | $995 |
$147
8,499
kWh
|
$488
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,200 | $2,920 |
$1,200
69,461
kWh
|
- | - | - | - | - | |
03 | 3.8125: Remove rollers from the machines and clean in a closed solvent cleaner | $1,180 | $1,000 | - | - | - | $910 | $270 | - | |
04 | 3.8132: Use less toxic and volatile solvent substitutes | $930 | - | - | - |
$760
-
lb
|
- | $170 | - | |
05 | 3.8132: Use less toxic and volatile solvent substitutes | $970 | - | - | - | - | - | $970 | - | |
06 | 3.6192: Use a less expensive method of waste removal | $360 | - | - | - |
$360
-
lb
|
- | - | - | |
07 | 4.451: Add additional production shift | $35,580 | $730 |
$(-190.0)
(-10,844)
kWh
|
- | - | $(-2,990.0) | - | $38,760 | |
08 | 4.514: Re-arrange equipment layout to reduce handling costs | $8,970 | $20,000 | - | - | - | $8,970 | - | - | |
TOTAL RECOMMENDED | $49,825 | $25,645 |
$1,157
67,116
kWh
|
$488
-
kW-mo/yr
|
$1,120
-
lb
|
$6,890 | $1,410 | $38,760 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs