Assessment Year | 1996 |
---|---|
Principal Product | dried poultry and meat products |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
55,000
ft2
|
Annual Production | 4,140,000
lb
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,367 | 2,385,111 |
kWh
|
$0.046 |
Electricity Fees | $(-2,158.0) | - |
|
- |
Natural Gas | $158,185 | 62,060 |
MMBtu
|
$2.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,325 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,895 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1172: Revise raw material specs | $8,100 | $1,000 | - | - |
$7,000
-
lb
|
$(-3,800.0) | $4,900 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,840 | $7,126 |
$1,840
40,739
kWh
|
- | - | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,720 | $1,500 | - |
$1,720
-
MMBtu
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $800 | $420 |
$800
17,585
kWh
|
- | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $105 | $290 |
$105
2,345
kWh
|
- | - | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $430 | $1,390 |
$430
9,672
kWh
|
- | - | - | - | |
07 | 2.2511: Insulate bare equipment | $200 | $120 |
$200
4,396
kWh
|
- | - | - | - | |
08 | 2.2511: Insulate bare equipment | $130 | $260 | - |
$130
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $13,325 | $12,106 |
$3,375
74,737
kWh
|
$1,850
-
MMBtu
|
$7,000
-
lb
|
$(-3,800.0) | $4,900 | ||
TOTAL IMPLEMENTED | $4,895 | $10,726 |
$3,175
70,341
kWh
|
$1,720
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs