| Assessment Year | 1994 |
|---|---|
| Principal Product | metal water control gates |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 68 |
| Plant Area |
110,000
ft2
|
| Annual Production | 4,300,600
lb
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $95,710 | 1,450,469 |
kWh
|
$0.066 |
| Natural Gas | $33,900 | 8,648 |
MMBtu
|
$3.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,400 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,070 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings | Gaseous Waste Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.7214: Reduce or eliminate waste | $27,620 | $15,000 | - | - |
$27,620
-
lb
|
- | |
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $6,830 | $7,860 |
$(-870.0)
(-13,189)
kWh
|
$7,700
-
MMBtu
|
- | - | |
| 03 | 2.2437: Recover waste heat from equipment | $820 | $820 | - |
$820
-
MMBtu
|
- | - | |
| 04 | 3.8125: Remove rollers from the machines and clean in a closed solvent cleaner | $2,210 | $1,750 | - | - | - |
$2,210
-
lb
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $1,590 | $2,260 |
$1,590
24,033
kWh
|
- | - | - | |
| 06 | 2.7134: Use photocell controls | $1,580 | $3,000 |
$1,580
24,033
kWh
|
- | - | - | |
| 07 | 3.2124: Convert to air assisted / airless paint guns | $1,310 | $1,300 | - | - | - |
$1,310
-
lb
|
|
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $880 | $370 |
$880
13,482
kWh
|
- | - | - | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $560 | $960 |
$560
8,499
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $43,400 | $33,320 |
$3,740
56,858
kWh
|
$8,520
-
MMBtu
|
$27,620
-
lb
|
$3,520
-
lb
|
||
| TOTAL IMPLEMENTED | $12,070 | $13,200 |
$2,160
32,825
kWh
|
$7,700
-
MMBtu
|
- |
$2,210
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (haz) Savings | Gaseous Waste Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs