Assessment Year | 1994 |
---|---|
Principal Product | newspapers |
NAICS |
n/a
|
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
38,000
ft2
|
Annual Production | 16,172,000
pieces
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,800 | 1,698,417 |
kWh
|
$0.055 |
Natural Gas | $10,900 | 2,711 |
MMBtu
|
$4.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,450 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,630 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,130 | $2,270 |
$2,130
38,980
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,070 | $150 |
$2,070
37,808
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $820 | $2,870 | - |
$820
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $430 | $1,390 |
$430
7,913
kWh
|
- | |
TOTAL RECOMMENDED | $5,450 | $6,680 |
$4,630
84,701
kWh
|
$820
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,630 | $3,810 |
$4,630
84,701
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs