| Assessment Year | 1993 |
|---|---|
| Principal Product | Printed Circuit Boards |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $5 M to 10M |
| # of Employees | 110 |
| Plant Area |
45,000
ft2
|
| Annual Production | 576
thousand feet
|
| Production Hrs. Annual | 4,106
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,894 | 1,577,374 |
kWh
|
$0.051 |
| Natural Gas | $18,827 | 5,158 |
MMBtu
|
$3.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,030 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $14,250 | $36,500 |
$20,460
398,886
kWh
|
$(-6,210.0)
-
MMBtu
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $2,520 | $650 | - |
$2,520
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,910 | $1,930 |
$1,910
37,222
kWh
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,200 | $2,520 |
$1,200
23,447
kWh
|
- | - | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $590 | $250 | - | - | $590 | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $530 | $150 |
$530
10,551
kWh
|
- | - | |
| TOTAL RECOMMENDED | $21,000 | $42,000 |
$24,100
470,106
kWh
|
$(-3,690.0)
-
MMBtu
|
$590 | ||
| TOTAL IMPLEMENTED | $3,030 | $2,330 |
$2,440
47,773
kWh
|
- | $590 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs