Assessment Year | 1993 |
---|---|
Principal Product | Injection Molded Plastics |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 485 |
Plant Area |
180,000
ft2
|
Annual Production | 5,500,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $195,659 | 3,847,011 |
kWh
|
$0.051 |
Natural Gas | $27,344 | 6,958 |
MMBtu
|
$3.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,890 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $1,930 | $250 | - | - | $1,930 | |
02 | 2.4221: Install compressor air intakes in coolest locations | $980 | $350 |
$980
19,343
kWh
|
- | - | |
03 | 2.4226: Use / purchase optimum sized compressor | $960 | $2,500 |
$960
50,703
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $400 | $820 |
$400
7,913
kWh
|
- | - | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $2,950 | $10,000 | - |
$2,950
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $7,220 | $13,920 |
$2,340
77,959
kWh
|
$2,950
-
MMBtu
|
$1,930 | ||
TOTAL IMPLEMENTED | $2,890 | $2,750 |
$960
50,703
kWh
|
- | $1,930 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs