ITAC Assessment: CO0239
ITAC logo
ITAC Assessment: CO0239
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product Construction lumber
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $1
M
to 5
M
# of Employees 65
Plant Area 50,000
ft2
Annual Production 40,000
thousand feet
Production Hrs. Annual 2,166
hrs
Location (State) Colorado

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $142,179 1,849,062
kWh
Other Energy $418 51
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $30,070 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,070

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Other Gas Savings Administrative Changes Savings
01 2.3212: Optimize plant power factor $13,400 $10,830 - - $13,400
02 2.7142: Utilize higher efficiency lamps and/or ballasts $5,330 $17,600 $5,330
69,168
kWh
- -
03 2.6212: Turn off equipment during breaks, reduce operating time $2,870 $680 $2,870
37,222
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,760 $500 $2,760
35,756
kWh
- -
05 2.2437: Recover waste heat from equipment $2,730 $670 $2,730
35,463
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,040 - $1,040
13,482
kWh
- -
07 2.7224: Reduce space conditioning during non-working hours $670 $125 $670
8,792
kWh
- -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $630 $2,360 $630
8,206
kWh
- -
09 2.7224: Reduce space conditioning during non-working hours $340 $150 - $340
-
MMBtu
-
10 2.7142: Utilize higher efficiency lamps and/or ballasts $300 $290 $300
3,810
kWh
- -
TOTAL RECOMMENDED $30,070 $33,205 $16,330
211,899
kWh
$340
-
MMBtu
$13,400
TOTAL IMPLEMENTED $30,070 $33,205 $16,330
211,899
kWh
$340
-
MMBtu
$13,400
Yearly Savings* Imp'd Cost* Electricity Usage Savings Other Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs