| Assessment Year | 1992 |
|---|---|
| Principal Product | Tofu, Tempeh |
| NAICS |
n/a
|
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
16,000
ft2
|
| Annual Production | 2,000,000
lb
|
| Production Hrs. Annual | 4,777
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,735 | 752,345 |
kWh
|
$0.054 |
| Natural Gas | $39,958 | 11,482 |
MMBtu
|
$3.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,860 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,860 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2136: Install / repair insulation on steam lines | $3,010 | $3,630 | - |
$3,010
-
MMBtu
|
|
| 02 | 2.2121: Increase amount of condensate returned | $1,090 | $2,500 | - |
$1,090
-
MMBtu
|
|
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $680 | $50 |
$680
26,377
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $340 | $170 |
$340
6,448
kWh
|
- | |
| 05 | 2.2212: Use minimum safe oven ventilation | $340 | $750 | - |
$340
-
MMBtu
|
|
| 06 | 2.2441: Preheat boiler makeup water with waste process heat | $600 | - | - |
$600
-
MMBtu
|
|
| 07 | 2.4133: Use most efficient type of electric motors | $330 | $770 |
$330
6,155
kWh
|
- | |
| 08 | 2.2511: Insulate bare equipment | $470 | $1,090 | - |
$470
-
MMBtu
|
|
| TOTAL RECOMMENDED | $6,860 | $8,960 |
$1,350
38,980
kWh
|
$5,510
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,860 | $8,960 |
$1,350
38,980
kWh
|
$5,510
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs