Assessment Year | 1991 |
---|---|
Principal Product | FABRICATED METAL |
NAICS |
n/a
|
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,704 | 414,127 |
kWh
|
$0.077 |
Natural Gas | $23,575 | 5,993 |
MMBtu
|
$3.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,664 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4323: Use optimum size and capacity equipment | $900 | $2,500 |
$900
11,723
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $561 | $157 |
$561
7,327
kWh
|
- | |
03 | 2.7314: Reduce ventilation air | $891 | $2,000 |
$157
2,052
kWh
|
$734
-
MMBtu
|
|
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $600 | $1,000 | - |
$600
-
MMBtu
|
|
05 | 2.2514: Cover open tanks | $823 | $580 | - |
$823
-
MMBtu
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $580 | $200 |
$580
7,620
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $83 | $242 |
$83
1,172
kWh
|
- | |
08 | 2.2511: Insulate bare equipment | $226 | $570 | - |
$226
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,664 | $7,249 |
$2,281
29,894
kWh
|
$2,383
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs