ITAC Assessment: CO0199
ITAC logo
ITAC Assessment: CO0199
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product CEMENT
NAICS
n/a
SIC 3241: Cement, Hydraulic
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area
n/a
Annual Production 376,000
ton
Production Hrs. Annual 6,570
hrs
Location (State) Wyoming

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,682,476 52,371,923
kWh
Natural Gas $436,342 102,423
MMBtu
Coal $1,096,874 1,680,065
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $112,809 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.8113: Purchase gas directly from a contract gas supplier $95,700 $6,000 - $95,700
-
MMBtu
02 2.4133: Use most efficient type of electric motors $3,580 $4,192 $3,580
111,958
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $13,200 $13,000 $13,200
412,661
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $329 $300 $329
10,258
kWh
-
TOTAL RECOMMENDED $112,809 $23,492 $17,109
534,877
kWh
$95,700
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs