Assessment Year | 1990 |
---|---|
Principal Product | PRINTED CIRCUIT BOARDS |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 4,860
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,401 | 480,950 |
kWh
|
$0.067 |
Natural Gas | $3,700 | 897 |
MMBtu
|
$4.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,263 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,744 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $2,076 | $200 |
$1,863
-
kWh
|
$213
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $1,080 | $700 |
$1,080
16,120
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $724 | $210 |
$724
10,844
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $350 | $400 | - |
$350
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $584 | $680 |
$584
8,499
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $360 | $150 |
$360
5,275
kWh
|
- | |
07 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,089 | $12,000 |
$(-813.0)
(-12,016)
kWh
|
$1,902
-
MMBtu
|
|
TOTAL RECOMMENDED | $6,263 | $14,340 |
$3,798
28,722
kWh
|
$2,465
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,744 | $1,240 |
$3,531
24,618
kWh
|
$213
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs