Assessment Year | 1990 |
---|---|
Principal Product | COMPUTER CHIP WAFERS |
NAICS |
n/a
|
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $10 M to 50M |
# of Employees | 450 |
Plant Area |
n/a
|
Annual Production | 54,000
pieces
|
Production Hrs. Annual | 6,990
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $951,927 | 25,983,002 |
kWh
|
$0.037 |
Natural Gas | $81,395 | 22,155 |
MMBtu
|
$3.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,568 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,896 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,042 | $3,930 |
$3,042
83,236
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,300 | $5,000 |
$5,300
145,076
kWh
|
- | |
03 | 2.4131: Size electric motors for peak operating efficiency | $2,630 | $5,000 |
$2,630
71,805
kWh
|
- | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,240 | $2,000 | - |
$2,240
-
MMBtu
|
|
05 | 2.2628: Utilize a less expensive cooling method | $10,356 | $44,000 |
$18,114
781,946
kWh
|
$(-7,758.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $23,568 | $59,930 |
$29,086
1,082,063
kWh
|
$(-5,518.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,896 | $51,000 |
$23,414
927,022
kWh
|
$(-5,518.0)
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs