| Assessment Year | 1990 |
|---|---|
| Principal Product | PLATING & ANODIZING |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $500 k to 1M |
| # of Employees | 20 |
| Plant Area |
n/a
|
| Annual Production | 2,000,000
pieces
|
| Production Hrs. Annual | 2,496
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,373 | 432,884 |
kWh
|
$0.075 |
| Natural Gas | $27,042 | 7,168 |
MMBtu
|
$3.77 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $2,600 | $2,900 |
$820
11,137
kWh
|
$1,780
-
MMBtu
|
|
| 02 | 2.2136: Install / repair insulation on steam lines | $760 | $2,360 | - |
$760
-
MMBtu
|
|
| 03 | 2.2514: Cover open tanks | $761 | $1,200 |
$166
2,345
kWh
|
$595
-
MMBtu
|
|
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,055 | $1,000 | - |
$1,055
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $175 | $74 |
$175
2,345
kWh
|
- | |
| 06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $380 | $300 |
$380
-
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22 | $105 |
$22
293
kWh
|
- | |
| TOTAL RECOMMENDED | $5,753 | $7,939 |
$1,563
16,120
kWh
|
$4,190
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs