Assessment Year | 1989 |
---|---|
Principal Product | IRON & STEEL CASTINGS |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 1,500,000
lb
|
Production Hrs. Annual | 3,474
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $104,521 | 2,010,844 |
kWh
|
$0.052 |
Natural Gas | $38,066 | 10,243 |
MMBtu
|
$3.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,790 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,290 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $720 | $700 | - |
$720
-
MMBtu
|
|
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $480 | $600 | - |
$480
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $900 | $500 |
$900
17,292
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $780 | $200 |
$780
14,947
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $570 | $400 | - |
$570
-
MMBtu
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $340 | $130 |
$340
6,448
kWh
|
- | |
TOTAL RECOMMENDED | $3,790 | $2,530 |
$2,020
38,687
kWh
|
$1,770
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,290 | $1,630 |
$1,240
23,740
kWh
|
$1,050
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs