| Assessment Year | 1988 |
|---|---|
| Principal Product | LAMB CARCASSES |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 750,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $103,574 | 2,143,611 |
kWh
|
$0.048 |
| Natural Gas | $98,569 | 27,064 |
MMBtu
|
$3.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,730 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,894 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8113: Purchase gas directly from a contract gas supplier | $14,785 | $2,000 | - |
$14,785
-
MMBtu
|
|
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,065 | $7,500 | - |
$1,065
-
MMBtu
|
|
| 03 | 2.1213: Direct warmest air to combustion intake | $948 | $1,000 | - |
$948
-
MMBtu
|
|
| 04 | 2.7444: Close holes and openings in building such as broken windows | $1,514 | $500 |
$793
16,413
kWh
|
$721
-
MMBtu
|
|
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,211 | $5,000 |
$1,127
23,447
kWh
|
$1,084
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,707 | $3,035 |
$2,707
55,979
kWh
|
- | |
| 07 | 2.2121: Increase amount of condensate returned | $911 | $1,000 | - |
$911
-
MMBtu
|
|
| 08 | 2.2414: Use waste heat from hot flue gases to preheat | $3,677 | $10,000 | - |
$3,677
-
MMBtu
|
|
| 09 | 2.2511: Insulate bare equipment | $659 | $1,000 | - |
$659
-
MMBtu
|
|
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $253 | $271 |
$253
5,275
kWh
|
- | |
| TOTAL RECOMMENDED | $28,730 | $31,306 |
$4,880
101,114
kWh
|
$23,850
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $21,894 | $15,306 |
$3,753
77,667
kWh
|
$18,141
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs