Assessment Year | 1988 |
---|---|
Principal Product | IRON AND STEEL CASTINGS |
NAICS |
n/a
|
SIC | 3462: Iron and Steel Forgings |
Sales Range | $10 M to 50M |
# of Employees | 400 |
Plant Area |
n/a
|
Annual Production | 25,000
ton
|
Production Hrs. Annual | 5,304
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,189,087 | 25,806,859 |
kWh
|
$0.046 |
Natural Gas | $138,564 | 48,239 |
MMBtu
|
$2.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,933 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,716 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,482 | $2,800 | - |
$5,482
-
MMBtu
|
- | |
02 | 2.2121: Increase amount of condensate returned | $896 | $200 | - |
$498
-
MMBtu
|
$398 | |
03 | 2.2511: Insulate bare equipment | $321 | $700 | - |
$321
-
MMBtu
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,341 | $2,000 |
$1,341
54,220
kWh
|
- | - | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $567 | $500 |
$567
22,860
kWh
|
- | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $1,817 | $250 |
$1,817
-
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,509 | $1,517 |
$1,509
32,825
kWh
|
- | - | |
TOTAL RECOMMENDED | $11,933 | $7,967 |
$5,234
109,905
kWh
|
$6,301
-
MMBtu
|
$398 | ||
TOTAL IMPLEMENTED | $10,716 | $7,067 |
$5,234
109,905
kWh
|
$5,482
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs