Assessment Year | 1986 |
---|---|
Principal Product | MILK AND ICE CREAM |
NAICS |
n/a
|
SIC | 2026: Fluid Milk |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 7,500
Tgal
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,267 | 2,956,038 |
kWh
|
$0.050 |
Natural Gas | $84,499 | 18,987 |
MMBtu
|
$4.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,170 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,922 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2121: Increase amount of condensate returned | $7,253 | $150 | - |
$7,253
-
MMBtu
|
|
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,654 | $300 | - |
$4,654
-
MMBtu
|
|
03 | 2.4312: Improve lubrication practices | $4,524 | - |
$4,524
89,683
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,159 | $1,800 |
$4,159
82,356
kWh
|
- | |
05 | 2.2441: Preheat boiler makeup water with waste process heat | $6,121 | $6,000 | - |
$6,121
-
MMBtu
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $2,221 | $800 |
$2,221
43,962
kWh
|
- | |
07 | 2.2135: Repair and eliminate steam leaks | $4,895 | $300 | - |
$4,895
-
MMBtu
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,811 | $150 |
$4,811
95,252
kWh
|
- | |
09 | 2.2136: Install / repair insulation on steam lines | $2,116 | $820 | - |
$2,116
-
MMBtu
|
|
10 | 2.2511: Insulate bare equipment | $493 | $560 |
$493
9,672
kWh
|
- | |
11 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,185 | $450 |
$3,185
63,013
kWh
|
- | |
12 | 2.7221: Lower temperature during the winter season and vice-versa | $518 | $500 | - |
$518
-
MMBtu
|
|
13 | 2.7221: Lower temperature during the winter season and vice-versa | $86 | - |
$86
1,758
kWh
|
- | |
14 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $15,747 | $30,000 |
$15,747
38,687
kWh
|
- | |
15 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,387 | $3,222 |
$3,387
67,116
kWh
|
- | |
TOTAL RECOMMENDED | $64,170 | $45,052 |
$38,613
491,499
kWh
|
$25,557
-
MMBtu
|
||
TOTAL IMPLEMENTED | $35,922 | $6,452 |
$16,486
326,494
kWh
|
$19,436
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs