Assessment Year | 2022 |
---|---|
Principal Product | Manufacturing Machines |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
68,000
ft2
|
Annual Production | 20
units
|
Production Hrs. Annual | 4,380
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $51,597 | 1,294,560 |
kWh
|
$0.040 | |
Electricity Demand | $61,113 | 3,045 |
kW-mo/yr
|
$20.07 | |
Electricity Fees | $11,994 | - |
|
- | |
Natural Gas | $7,688 | 1,212 |
MMBtu
|
$6.34 | |
Waste Disposal Costs | |||||
Water Usage | $3,218 | 579 |
Tgal
|
$5.56 | |
TOTAL YEARLY COSTS | $135,610 | ||||
RECOMMENDED SAVINGS* | $66,932 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $29,820 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $30,400 | $894,000 |
$22,400
562,600
kWh
|
$8,000
-
kW-mo/yr
|
- | - | - | |
02 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $2,098 | $10,625 |
$18
450
kWh
|
- | - | $2,080 | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $454 | $25 |
$400
10,010
kWh
|
$54
-
kW-mo/yr
|
- | - | - | |
04 | 2.7272: Install heat pipes / raise cooling setpoint | $118 | - |
$70
1,752
kWh
|
$48
-
kW-mo/yr
|
- | - | - | |
05 | 2.4322: Use or replace with energy efficient substitutes | $156 | $500 |
$140
3,500
kWh
|
$16
-
kW-mo/yr
|
- | - | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $4,160 | $8,000 | - | - | $4,160 | - | - | |
07 | 2.7141: Lower light fixtures in high ceiling areas | $29,546 | $160,998 |
$(-1,020.0)
(-25,500)
kWh
|
$(-84.0)
-
kW-mo/yr
|
- | - | $30,650 | |
TOTAL RECOMMENDED | $66,932 | $1,074,148 |
$22,008
552,812
kWh
|
$8,034
-
kW-mo/yr
|
$4,160 | $2,080 | $30,650 | ||
TOTAL IMPLEMENTED | $29,820 | $161,498 |
$(-810.0)
(-20,248)
kWh
|
$(-20.0)
-
kW-mo/yr
|
- | - | $30,650 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs