Assessment Year | 2021 |
---|---|
Principal Product | Portable Water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $500 k to 1M |
# of Employees | 20 |
Plant Area |
10,804
ft2
|
Annual Production | 100,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $201,249 | 3,258,400 |
kWh
|
$0.062 |
Electricity Fees | $15,499 | - |
|
- |
TOTAL YEARLY COSTS | $216,748 | |||
RECOMMENDED SAVINGS* | $43,566 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,074 | $19,482 |
$6,074
98,349
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,152 | $2,480 |
$1,152
18,634
kWh
|
- | - | |
03 | 4.463: Modify facility to avoid excess maintenance costs | $950 | $4,500 | - | - | $950 | |
04 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $35,390 | - |
$1,125
18,218
kWh
|
$34,265
-
Tgal
|
- | |
TOTAL RECOMMENDED | $43,566 | $26,462 |
$8,351
135,201
kWh
|
$34,265
-
Tgal
|
$950 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs