Assessment Year 2017
Principal Product Zinc Nickle platings of Coatings, forgings, stampings, E-coatings, powde
NAICS 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring
Sales Range $10
M
to 50
M
# of Employees 112
Plant Area 170,000
ft2
Annual Production 50,000,000
units
Production Hrs. Annual 7,200
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $391,384 5,937,160
kWh
Electricity Demand $5,165 516
kW-mo/yr
Natural Gas $232,573 44,192
MMBtu
Waste Disposal Costs
Water Usage $36,562 16,177
Tgal
TOTAL YEARLY COSTS $665,684
RECOMMENDED SAVINGS* $56,445 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,281

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings
01 3.4115: Recover and reuse cooling water $31,006 - - - - $31,006
-
Tgal
02 2.2421: Install waste heat boiler to provide direct power $11,470 $15,000 - - $11,470
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $8,811 $21,000 $6,843
103,803
kWh
$1,968
-
kW-mo/yr
- -
04 3.4156: Use flow control valves on equipment to optimize water use $3,656 $3,050 - - - $3,656
-
Tgal
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,502 $900 $1,032
15,652
kWh
$470
-
kW-mo/yr
- -
TOTAL RECOMMENDED $56,445 $39,950 $7,875
119,455
kWh
$2,438
-
kW-mo/yr
$11,470
-
MMBtu
$34,662
-
Tgal
TOTAL IMPLEMENTED $20,281 $36,000 $6,843
103,803
kWh
$1,968
-
kW-mo/yr
$11,470
-
MMBtu
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs