| Assessment Year | 2026 |
|---|---|
| Principal Product | Aluminum Forgings |
| NAICS | 332112: Nonferrous Forging |
| SIC | 3463: Nonferrous Forgings |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
50,000
ft2
|
| Annual Production | 100,000
units
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $556,196 | 3,770,876 |
kWh
|
$0.15 | |
| Electricity Demand | $354,281 | 11,874 |
kW-mo/yr
|
$29.84 | |
| Electricity Fees | $109,106 | - |
|
- | |
| Natural Gas | $488,996 | 48,152 |
MMBtu
|
$10.16 | |
| LPG | $66,000 | 2,011 |
MMBtu
|
$32.82 | |
| Other Gas | $27,085 | 1 |
MMBtu
|
$27,085.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $22,956 | 4,139 |
Tgal
|
$5.55 | |
| Water Disposal | $1,450 | 4,139 |
Tgal
|
$0.35 | |
| Other Liquid (non-haz) | $7,246 | 1 |
gal
|
$7,246.00 | |
| TOTAL YEARLY COSTS | $1,633,316 | ||||
| RECOMMENDED SAVINGS* | $559,562 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $254,250 | $420,000 | - | - |
$122,250
-
MMBtu
|
- | $132,000 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $149,013 | $8,400 |
$124,780
845,964
kWh
|
$24,233
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $45,925 | $176,000 |
$(-12,980.0)
(-88,000)
kWh
|
$(-7,095.0)
-
kW-mo/yr
|
- |
$66,000
-
MMBtu
|
- | |
| 04 | 2.1122: Re-size charging openings or add a movable door on equipment | $40,621 | $150,000 | - | - |
$40,621
-
MMBtu
|
- | - | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $30,034 | $3,000 |
$22,007
149,200
kWh
|
$8,027
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.2442: Preheat combustion air with waste heat | $22,139 | $15,840 | - | - |
$22,139
-
MMBtu
|
- | - | |
| 07 | 2.9114: Use solar heat to make electricty | $13,645 | $73,418 |
$10,213
69,240
kWh
|
$3,432
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.2511: Insulate bare equipment | $3,935 | $500 |
$2,649
17,961
kWh
|
$1,286
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $559,562 | $847,158 |
$146,669
994,365
kWh
|
$29,883
-
kW-mo/yr
|
$185,010
-
MMBtu
|
$66,000
-
MMBtu
|
$132,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs