| Assessment Year | 2026 |
|---|---|
| Principal Product | Flow, pH conductivity, sensors and transmitters |
| NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
70,000
ft2
|
| Annual Production | 599,875
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $76,635 | 684,429 |
kWh
|
$0.11 | |
| Electricity Demand | $84,449 | 2,378 |
kW-mo/yr
|
$35.51 | |
| Electricity Fees | $31,006 | - |
|
- | |
| Natural Gas | $610 | 23 |
MMBtu
|
$26.52 | |
| Other Gas | $75 | 1 |
MMBtu
|
$75.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,690 | 714 |
Tgal
|
$3.77 | |
| Other Liquid (non-haz) | $6,297 | 1 |
gal
|
$6,297.00 | |
| TOTAL YEARLY COSTS | $201,762 | ||||
| RECOMMENDED SAVINGS* | $114,733 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $49,830 | $628,346 |
$31,635
282,460
kWh
|
$18,195
-
kW-mo/yr
|
- | |
| 02 | 2.3141: Use battery storage for demand control | $31,353 | $40,000 |
$5,431
121,055
kWh
|
$25,922
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,741 | $4,600 |
$10,116
90,323
kWh
|
$8,625
-
kW-mo/yr
|
- | |
| 04 | 2.3132: Recharge batteries on during off-peak demand periods | $7,670 | $100 | - |
$7,670
-
kW-mo/yr
|
- | |
| 05 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,024 | $10,000 |
$4,024
45,234
kWh
|
- | - | |
| 06 | 2.5123: Reduce fluid flow rates | $2,078 | $8,000 | - | - |
$2,078
-
Tgal
|
|
| 07 | 2.6218: Turn off equipment when not in use | $1,037 | $500 |
$1,037
9,263
kWh
|
- | - | |
| TOTAL RECOMMENDED | $114,733 | $691,546 |
$52,243
548,335
kWh
|
$60,412
-
kW-mo/yr
|
$2,078
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs