Assessment Year | 2025 |
---|---|
Principal Product | Ready Mix Concrete |
NAICS | 327320: Ready-Mix Concrete Manufacturing |
SIC | 3273: Ready-Mixed Concrete |
Sales Range | $1 M to 5M |
# of Employees | 31 |
Plant Area |
88,180
ft2
|
Annual Production | 274,054
units
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $127,886 | 762,000 |
kWh
|
$0.17 | |
Electricity Demand | $55,193 | 3,931 |
kW-mo/yr
|
$14.04 | |
Electricity Fees | $24,273 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $132,307 | 9,445 |
Tgal
|
$14.01 | |
Water Disposal | $17,549 | 9,445 |
Tgal
|
$1.86 | |
TOTAL YEARLY COSTS | $357,208 | ||||
RECOMMENDED SAVINGS* | $98,558 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $47,726 | $259,574 |
$42,793
255,028
kWh
|
$4,933
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,837 | $4,300 |
$16,339
97,371
kWh
|
$1,498
-
kW-mo/yr
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $15,348 | $4,370 |
$13,526
80,606
kWh
|
$1,822
-
kW-mo/yr
|
- | |
04 | 2.3141: Use battery storage for demand control | $14,647 | $22,685 |
$3,609
21,509
kWh
|
$11,038
-
kW-mo/yr
|
- | |
05 | 4.651: Install back-up equipment | $3,000 | $300 | - | - | $3,000 | |
TOTAL RECOMMENDED | $98,558 | $291,229 |
$76,267
454,514
kWh
|
$19,291
-
kW-mo/yr
|
$3,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs