Assessment Year | 2015 |
---|---|
Principal Product | Point of Sale Systems |
NAICS | 333318: Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3578: Calculating and Accounting Machines, Except Electronic Computers |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
245,000
ft2
|
Annual Production | 20,000
pieces
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $196,206 | 2,528,269 |
kWh
|
$0.078 |
Electricity Demand | $82,503 | 8,548 |
kW-mo/yr
|
$9.65 |
Electricity Fees | $55,732 | - |
|
- |
Natural Gas | $5,871 | 993 |
MMBtu
|
$5.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,764 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,142 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $2,133 | - |
$1,264
16,200
kWh
|
$869
-
kW-mo/yr
|
- | - | |
02 | 2.7122: Disconnect ballasts | $2,373 | - |
$1,562
20,020
kWh
|
$811
-
kW-mo/yr
|
- | - | |
03 | 2.4314: Use synthetic lubricant | $1,717 | - |
$1,138
14,588
kWh
|
$579
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $452 | $211 |
$75
963
kWh
|
$13
-
kW-mo/yr
|
$250 | $114 | |
05 | 3.1161: Eliminate/reduce an operation | $4,789 | $5,450 |
$(-753.0)
(-9,660)
kWh
|
$(-347.0)
-
kW-mo/yr
|
$2,025 | $3,864 | |
06 | 2.4321: Upgrade obsolete equipment | $446 | $958 |
$381
4,888
kWh
|
$65
-
kW-mo/yr
|
- | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $460 | $950 |
$460
5,903
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,394 | $50,904 |
$14,036
179,945
kWh
|
$3,358
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $29,764 | $58,473 |
$18,163
232,847
kWh
|
$5,348
-
kW-mo/yr
|
$2,275 | $3,978 | ||
TOTAL IMPLEMENTED | $22,142 | $52,073 |
$16,894
216,584
kWh
|
$4,884
-
kW-mo/yr
|
$250 | $114 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs