| Assessment Year | 2025 |
|---|---|
| Principal Product | Tortilla Chips, Taco Shells & Pellet Snacks |
| NAICS | 311919: Other Snack Food Manufacturing |
| SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
| Sales Range | $50 M to 100M |
| # of Employees | 230 |
| Plant Area |
133,665
ft2
|
| Annual Production | 30,000,000
lb
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $809,513 | 3,557,422 |
kWh
|
$0.23 | |
| Electricity Demand | $233,366 | 17,164 |
kW-mo/yr
|
$13.60 | |
| Electricity Fees | $59,426 | - |
|
- | |
| Natural Gas | $1,583,938 | 105,280 |
MMBtu
|
$15.05 | |
| Other Gas | $101,940 | 1 |
MMBtu
|
$101,940.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $276,674 | 9,180 |
Tgal
|
$30.14 | |
| TOTAL YEARLY COSTS | $3,064,857 | ||||
| RECOMMENDED SAVINGS* | $794,604 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $316,788 | $3,200,000 | - | - |
$316,788
-
MMBtu
|
|
| 02 | 2.9114: Use solar heat to make electricty | $159,105 | $669,600 |
$146,049
651,000
kWh
|
$13,056
-
kW-mo/yr
|
- | |
| 03 | 2.2442: Preheat combustion air with waste heat | $127,862 | $20,000 |
$118,122
518,991
kWh
|
$9,740
-
kW-mo/yr
|
- | |
| 04 | 2.2515: Use optimum thickness insulation | $67,904 | $174,000 |
$67,904
298,346
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $57,280 | $7,800 |
$51,862
227,864
kWh
|
$5,418
-
kW-mo/yr
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $26,465 | $20,000 |
$23,821
104,662
kWh
|
$2,644
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,542 | $3,762 |
$13,640
59,928
kWh
|
$3,902
-
kW-mo/yr
|
- | |
| 08 | 2.7134: Use photocell controls | $14,804 | $4,000 |
$10,897
47,880
kWh
|
$3,907
-
kW-mo/yr
|
- | |
| 09 | 2.3132: Recharge batteries on during off-peak demand periods | $6,854 | $200 | - |
$6,854
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $794,604 | $4,099,362 |
$432,295
1,908,671
kWh
|
$45,521
-
kW-mo/yr
|
$316,788
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs