ITAC Assessment: CI0050
ITAC logo
ITAC Assessment: CI0050
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product In-Flight Entertainment Systems
NAICS 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 168
Plant Area 71,656
ft2
Annual Production 1,000,000
units
Production Hrs. Annual 2,340
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $154,035 1,436,707
kWh
Electricity Demand $132,380 7,362
kW-mo/yr
Electricity Fees $7,705 -
Natural Gas $10,820 763
MMBtu
Waste Disposal Costs
Water Usage $1,290 391
Tgal
Water Disposal $1,439 391
Tgal
TOTAL YEARLY COSTS $307,669
RECOMMENDED SAVINGS* $195,625 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.9114: Use solar heat to make electricty $87,810 $829,924 $67,572
630,336
kWh
$20,238
-
kW-mo/yr
02 2.4322: Use or replace with energy efficient substitutes $45,303 $310,000 $35,287
329,173
kWh
$10,016
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $41,763 $5,000 $34,607
322,827
kWh
$7,156
-
kW-mo/yr
04 2.4239: Eliminate or reduce compressed air usage $8,212 $3,000 $7,006
65,350
kWh
$1,206
-
kW-mo/yr
05 2.3137: Use power during off-peak periods $7,726 $11,000 - $7,726
-
kW-mo/yr
06 2.3132: Recharge batteries on during off-peak demand periods $2,037 $120 - $2,037
-
kW-mo/yr
07 2.7134: Use photocell controls $1,562 $1,012 $613
5,720
kWh
$949
-
kW-mo/yr
08 2.6212: Turn off equipment during breaks, reduce operating time $1,212 $150 $1,212
11,303
kWh
-
TOTAL RECOMMENDED $195,625 $1,160,206 $146,297
1,364,709
kWh
$49,328
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs