| Assessment Year | 2025 |
|---|---|
| Principal Product | Powder Metallurgy |
| NAICS | 332117: Powder Metallurgy Part Manufacturing |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 23 |
| Plant Area |
70,000
ft2
|
| Annual Production | 1,000,000
units
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $70,108 | 556,274 |
kWh
|
$0.13 | |
| Electricity Demand | $47,116 | 3,359 |
kW-mo/yr
|
$14.03 | |
| Electricity Fees | $2,464 | - |
|
- | |
| Natural Gas | $30,524 | 2,779 |
MMBtu
|
$10.98 | |
| Other Gas | $4,334 | 1 |
MMBtu
|
$4,334.00 | |
| Other Energy | $349,950 | 1 |
MMBtu
|
$349,950.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,969 | 436 |
Tgal
|
$6.81 | |
| Other Liquid (non-haz) | $2,178 | 1 |
gal
|
$2,178.00 | |
| TOTAL YEARLY COSTS | $509,643 | ||||
| RECOMMENDED SAVINGS* | $469,956 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.212: Adopt in-house material generation | $349,950 | $1,386,072 | - | - |
$349,950
-
MMBtu
|
|
| 02 | 2.9114: Use solar heat to make electricty | $35,660 | $280,607 |
$26,936
213,774
kWh
|
$8,724
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $24,870 | $5,200 |
$21,604
171,460
kWh
|
$3,266
-
kW-mo/yr
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $19,096 | $20,568 |
$14,648
116,250
kWh
|
$4,448
-
kW-mo/yr
|
- | |
| 05 | 2.2511: Insulate bare equipment | $17,211 | $5,150 |
$17,211
136,600
kWh
|
- | - | |
| 06 | 2.2442: Preheat combustion air with waste heat | $16,338 | $9,000 |
$7,718
61,251
kWh
|
$8,620
-
kW-mo/yr
|
- | |
| 07 | 2.3132: Recharge batteries on during off-peak demand periods | $3,571 | $40 | - |
$3,571
-
kW-mo/yr
|
- | |
| 08 | 2.7232: Replace existing hvac unit with high efficiency model | $2,103 | $2,000 |
$2,103
16,688
kWh
|
- | - | |
| 09 | 2.7135: Install occupancy sensors | $1,157 | $2,000 |
$764
6,061
kWh
|
$393
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $469,956 | $1,710,637 |
$90,984
722,084
kWh
|
$29,022
-
kW-mo/yr
|
$349,950
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs