ITAC Assessment: CI0027
ITAC logo
ITAC Assessment: CI0027
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Additive Manufactured Goods
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 31
Plant Area 16,000
ft2
Annual Production 500,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $111,099 820,619
kWh
Electricity Demand $61,572 1,566
kW-mo/yr
Electricity Fees $10,558 -
TOTAL YEARLY COSTS $183,229
RECOMMENDED SAVINGS* $124,052 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.9114: Use solar heat to make electricty $64,706 $1,076,000 $46,937
346,658
kWh
$17,769
-
kW-mo/yr
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $24,353 $300 $18,758
138,541
kWh
$5,595
-
kW-mo/yr
03 2.7232: Replace existing hvac unit with high efficiency model $16,307 $15,500 $16,307
120,440
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $5,618 $2,442 $3,593
26,534
kWh
$2,025
-
kW-mo/yr
05 2.7135: Install occupancy sensors $3,632 $3,000 $3,058
22,586
kWh
$574
-
kW-mo/yr
06 2.4231: Reduce the pressure of compressed air to the minimum required $3,620 - $2,590
19,127
kWh
$1,030
-
kW-mo/yr
07 2.7134: Use photocell controls $3,161 $1,400 $1,085
8,013
kWh
$2,076
-
kW-mo/yr
08 2.4239: Eliminate or reduce compressed air usage $2,655 $500 $2,655
19,605
kWh
-
TOTAL RECOMMENDED $124,052 $1,099,142 $94,983
701,504
kWh
$29,069
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs