Assessment Year | 2024 |
---|---|
Principal Product | Additive Manufactured Goods |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 31 |
Plant Area |
16,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $111,099 | 820,619 |
kWh
|
$0.14 |
Electricity Demand | $61,572 | 1,566 |
kW-mo/yr
|
$39.32 |
Electricity Fees | $10,558 | - |
|
- |
TOTAL YEARLY COSTS | $183,229 | |||
RECOMMENDED SAVINGS* | $124,052 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $64,706 | $1,076,000 |
$46,937
346,658
kWh
|
$17,769
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $24,353 | $300 |
$18,758
138,541
kWh
|
$5,595
-
kW-mo/yr
|
|
03 | 2.7232: Replace existing hvac unit with high efficiency model | $16,307 | $15,500 |
$16,307
120,440
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,618 | $2,442 |
$3,593
26,534
kWh
|
$2,025
-
kW-mo/yr
|
|
05 | 2.7135: Install occupancy sensors | $3,632 | $3,000 |
$3,058
22,586
kWh
|
$574
-
kW-mo/yr
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,620 | - |
$2,590
19,127
kWh
|
$1,030
-
kW-mo/yr
|
|
07 | 2.7134: Use photocell controls | $3,161 | $1,400 |
$1,085
8,013
kWh
|
$2,076
-
kW-mo/yr
|
|
08 | 2.4239: Eliminate or reduce compressed air usage | $2,655 | $500 |
$2,655
19,605
kWh
|
- | |
TOTAL RECOMMENDED | $124,052 | $1,099,142 |
$94,983
701,504
kWh
|
$29,069
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs